Temperature Protection in 
NEMA-Rated Enclosures
InView P42, P43, P44, P72, and P74 signs have automatic temperature 
controls that help to protect the sign from damage when the internal 
temperature of the sign is too hot to continue normal operation.
•
If the internal temperature of the sign reaches a pre-determined 
“dimming point”, the LED output from the sign is forced into a 
50 percent reduced power mode, effectively dimming the 
brightness of LED output by about 50 percent.
•
If the internal temperature of the sign continues to increase, 
another sensing circuit will execute an automatic shut down to 
protect the sign from damage. The LED output from the sign is 
turned off.
•
The dimming and shutdown points are listed in the table below. 
Once the temperature drops below the auto-shutdown 
threshold, the LED output is turned on at the dimming level. 
Once the temperature drops below the dimming threshold, 
auto-dimming is disabled and the LED brightness is back to 100 
percent.
Table B
Model
Enclosure
Dimming Point
Auto-Shutdown On
2706-P42, 2706-P44
NEMA 12
55°C (131°F)
70°C (158°F)
2706-P43
NEMA 12
55°C (131°F)
70°C (158°F)
2706-P72, 2706-P74
NEMA 4, NEMA 4x
55°C (131°F)
70°C (158°F)
TIP
Take into account the effects of ambient temperature 
when evaluating mounting locations for the sign. 
You should always maintain recommended clearance 
distances around the sign and avoid poorly 
ventilated mounting locations that could be subject 
to radiation, convection, conduction or other thermal 
transfer effects.