3. Use two 10-32 x 1/4 Phillips screws (supplied) to secure the wall
mounting bracket to the back of the sign. Torque the screws to 
2.7 Nm (24 in-lb).
4. Replace the end cap using the 4 screws removed in Step 1
above. Torque the screws to 2.7 Nm (24 in-lb).
5. Repeat Steps 1 to 4 for the other end of the sign. Distances
between the bracket holes, center-to-center, should be 
approximately:
6. Attach the two remaining wall mounting brackets to a wall so
that they align with the brackets on the sign.
7. Connect the mounting brackets on each end of the sign together
using a 5/16 Phillips screw and a 5/16 washer through the 
mounting holes, as shown below, securing with a 5/16 nut. Do 
not tighten the nut at this time.
Phillips 
screws go 
here.
Fasten 
these 
screws.
TIP
Do NOT install the sign directly to drywall or 
plaster-board. The sign must be fastened to a wall 
capable of supporting at least four times the weight 
of the sign.
37 in (94 cm) for 2706-P42 and