Rockwell Automation 2706-P42R_P42C_P43R_P43C_P44R_P44C_P72CNx_P74CNx InView Marquee Message Display User Manual
Page 4

Publication 2706-IN006E-EN-P
InView Marquee Message Display 3
3. Insert the power wires through the left conduit hole on either
the top or the bottom of the sign. The bottom conduit hole is
recommended to reduce noise from power wires crossing serial
wires.
4. Strip the wires back 1/4”. Connect the incoming electrical wires.
Be sure to place the wires so they are not caught by screws
when replacing the power supply cover, and also so they do not
interfere with fan operation.
5. Insert the serial wires through the right conduit hole on either
the top or the bottom of the sign.
TIP
Use watertight conduit connectors only.
Flexible conduit should be used.
Insert the
power wires
into one of
these
conduits.
Internal
serial wires
Internal wiring for
power supply
H
N
Hot (Line 1)
Ground
Neutral
(Line 2)
Neutral
(Line 2):
Line
(Hot)
Ground
GREEN
w/
100 – 240 VAC
@ 50/60 Hz
Insert the
serial wires