Rockwell Automation 2706-P42R_P42C_P43R_P43C_P44R_P44C_P72CNx_P74CNx InView Marquee Message Display User Manual
Page 6
 
Publication 2706-IN006E-EN-P
InView Marquee Message Display 5
9. P1 can be used for incoming RS-232 only, although it is optional
and not recommended. P1 is intended for RS-232 application 
downloads and RS-485 terminating resistor connection. See 
publication 2706-IN007 for more information on RS-485 
termination.
10. To maintain NEMA compliance and to prevent EMI emissions,
install hole plugs in any open conduit holes in the power supply 
enclosure. If needed, there is an extra hole plug supplied in 
addition to any hole plugs removed in Step 2 on page 2.
11. Replace the power supply cover using the 6 screws from when
the cover was removed. (Refer to Step 1 on page 2.) Torque the screws 
to 2.7 Nm (24 in-lb).
12. Connect the power cable to a power source.
Mounting Instructions 
2706-P42, 2706-P43 and 
2706-P44
Before mounting a sign, remove power from the sign.
P1
Incoming 
serial wires
TIP
Be sure to place the wires so they are not caught by 
screws when replacing the power supply cover, and 
also so they do not interfere with fan operation.
TIP
Only qualified personnel should install the InView 
signs.
InView signs are for indoor use only and should not 
be continuously exposed to direct sunlight.
Mounting hardware that is used to hang or suspend 
signs must be capable of supporting at least 4 times 
the total weight of any/all signs mounted together.
For integrity of the case, do not drill holes in or 