Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 12

Advertising
background image

Overview

1–4

LED Indicators

Seven LEDs provide the following indications.

Indicator

Condition

Indicates:

Green

Normal operating state

Flashing Green

Initialization and/or incorrect (unconfigured)
configuration

Module

Red

Processor fault (nonrecoverable)

Module

Flashing Red

Minor fault (recoverable). Occurs when down-
loading firmware.

Off

No power applied to Reader

Green

Normal DeviceNet operating state

Flashing Green

Communication link established, but not data
transfer.

Netw r

Red

Communication fault

Network

Flashing Red

One or more DeviceNet devices are not re-
sponding. Reader may not be able to perform
all configured functions.

Off

DeviceNet communications not established

La er

Yellow

Scan beam on

Laser On

Off

Scan beam off

Yellow

Scanning and decoding bar code symbol

On Symbol

Flashing

Bar code symbol read at less than 100% rate

On Symbol

Off

Not scanning bar code symbol

Yellow

Package detected

Trigger / Read

Green

Valid read

Trigger / Read

Off

No trigger or no valid bar code symbol read

I/ 1

Yellow

Input/Output module 1 active

I/O 1

Off

Input/Output module 1 not active

I/ 2

Yellow

Input/Output module 2 active

I/O 2

Off

Input/Output module 2 not active

Wiring Base Connector

The 24-pin connector on the bottom of the Reader plugs into the
socket on the wiring base. No other connections to the Reader are
required.

Operating Environment

The Reader operates under a variety of conditions.

Cast aluminum enclosure meets NEMA Type 4 requirements
when used with the wiring base.

Operates in environments from 32 to 122

_F (0 to 50_C).

Mounts at any angle.

See Appendix A for a complete list of Reader specifications.