4 - installing / removing the reader, Chapter objectives, Installation – Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 59: Installing / removing the reader, Chapter

Advertising
background image

Chapter

4

Installing / Removing the

Reader

This chapter describes how to install the Reader on the wiring base.

Section

Page

Installation

4–1

Power-up Sequence

4–2

Checking Reader Operation

4–2

Replacing a Reader

4–3

The Reader plugs into the connector on the wiring base. Install the
Reader with or without the power disconnected from the wiring base.

To install the Reader:

Captive Screws
4 Locations
Tighten to 18 inch-pounds

(2.0 N

S

m)

Wiring Base
Insulating Cover

1. Make sure the insulating cover with warning label attached is in

position, so the flap covers the field wiring connections inside the
wiring base.

2. Place the Reader over the wiring base and carefully align the

connector on the bottom of the Reader with the connector on the
wiring base (to avoid bending pins).

3. Press Reader down firmly until it contacts the wiring base.

4. Secure the Reader with four screws. Alternately tighten screws to

a torque of 18 inch-pounds (2.0 N

Sm).

Chapter Objectives

Installation