Troubleshooting and Maintenance

6–4

Network

Condition

Indication

Green

Normal DeviceNet operating state.

Flashing Green

Communication link established but no data transfer.

Red

DeviceNet communication fault detected.

Flashing Red

One or more DeviceNet devices are not responding. Reader may
not be able to perform all configured functions.

Off

No DeviceNet communications established.

Laser On

Condition

Indication

Yellow

The scan beam is On (active).

Off

The scan beam is Off (inactive).

Module

Condition

Indication

Green

Normal operating condition. Power is applied to the Reader and no
faults have been detected.

Flashing Green

Power-up initialization or incorrect configuration.

Red

Processor fault (unrecoverable).

Flashing Red

Minor fault (recoverable). Occurs when downloading firmware.

Off

No power applied to Reader.