Package detector – Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 57

Advertising
background image

Installing the Wiring Base and Power Supply

3–22

The package detect input accepts only a current sinking output.
Allen-Bradley Photoswitch

r package detectors are recommended.

Select a switch from the PhotoSeries 6000 or 9000 product line that
best suits your application. Make sure you order a sinking (12V
DC) type sensor. Mounting brackets and cables are also available.

Important: Package detect terminals are not powered until a Reader
is installed on the wiring base.

The package detector must be able to operate using the +12V DC
source (12V) and not draw more than 100mA. The package detect
sense line (TRG) must be able to sink 5mA at +12V DC.

Follow these guidelines when installing a package detector.

Mount the package detector and reflector so that the scan beam
does not strike either of them.

Install the reflector within the operating range of the package
detector.

The package detector beam must be broken before the label is in
position for scanning. The package detect should remain active
while the symbol is being scanned.

Grounding the trigger (on Package Detect terminals in wiring
base) activates the package detect (scanner).

Package Detector