Read ranges – Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 34

Advertising
background image

Installation Considerations

2–8

The following tables show tabular read range limits for the three
versions of the AdaptaScan Readers.

Table 2.A
Read Ranges, Catalog No. 2755-SN3
➀

Minimum Apparent Element Width➁

Read Range ➂

Mils

mm

Inches

Meters

5
6

7.5

10
13
15
20
25
30
35
40
45
50
55

.13
.15
.19
.25
.33
.38
.51
.64
.75
.89

1.02
1.14
1.27
1.40

1.9 -

3.6

1.9 -

5.3

1.4 -

7.2

1.4 - 10.9
1.4 - 16.2
1.4 - 19.5
1.4 - 28.4
1.4 - 36.8
1.9 - 42.9
1.9 - 51.4
1.9 - 59.3
2.4 - 64.4
2.9 - 69.4
3.4 - 74.6

.048 - .092
.048 - .135
.036 - .183
.036 - .277
.036 - .411
.036 - .495
.036 - .721
.036 - .935
.048 - 1.09
.048 - 1.31
.048 - 1.51
.061 - 1.64
.074 - 1.76
.086 - 1.89

Table 2.B
Read Ranges Catalog No. 2755-SN5
➀

Minimum Apparent Element Width➁

Read Range ➂

Mils

mm

Inches

Meters

5
6

7.5

10
13
15
20
25
30
35
40
45
50
55

.13
.15
.19
.25
.33
.38
.51
.64
.75
.89

1.02
1.14
1.27
1.40

1.9 -

4.7

1.9 -

7.3

1.9 -

8.9

1.4 - 14.0
1.4 - 19.5
1.9 - 21.8
1.9 - 29.7
2.4 - 36.2
2.4 - 42.5
2.4 - 51.5
3.4 - 56.9
3.9 - 61.9
4.4 - 67.9
5.4 - 71.6

.048 - .119
.048 - .185
.048 - .226
.036 - .356
.036 - .495
.048 - .554
.048 - .754
.061 - .919
.061 - 1.08
.061 - 1.31
.086 - 1.44
.099 - 1.57
.112 - 1.72
.137 - 1.82

Table 2.C
Read Ranges Catalog No. 2755-SN8
➀

Minimum Apparent Element Width ➁

Mils mm

Read Range ➂

Inches

Meters

5
6

7.5

10
13
15
20
25
30
35
40
45
50
55

.13
.15
.19
.25
.33
.38
.51
.64
.75
.89

1.02
1.14
1.27
1.40

1.4 -

5.7

1.4 -

8.2

1.4 - 10.7
1.4 - 16.0
1.4 - 21.0
1.9 - 25.4
2.4 - 34.3
3.4 - 42.2
5.4 - 50.2
6.4 - 55.6
7.4 - 62.1
8.4 - 65.4

10.4 - 69.0

11.4 - 72.5

.036 - .145
.036 - .208
.036 - .272
.036 - .406
.036 - .533
.048 - .645
.061 - .871
.086 - .107
.137 - 1.27
.163 - 1.41
.188 - 1.58
.213 - 1.66
.264 - 1.75
.290 - 1.84

Read Ranges

Read ranges based on four character Code
39 labels with a wide to narrow bar ratio of
2.6 to 1 and a print contrast ratio of .75 or
better. Read ranges will vary with bar code
symbol quality.

When scanning labels at an angle apparent
element width is less than the actual element
width.

Read ranges measured from front edge of
wiring base. Add .58 inches (.015 meter) for
the distance to the scan window.

➀

➁

➂

Read Range