3 - installing the wiring base and power supply, Chapter objectives, General mounting guidelines – Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 36: Installing the wiring base and power supply, Chapter, Chapter objectives general mounting guidelines

Advertising
background image

Chapter

3

Installing the Wiring Base and

Power Supply

This chapter describes how to install and mount the wiring base.

Section

Page

General Mounting Guidelines

3–1

Dimensions and Clearances

3–2

Mounting the Wiring Base

3–4

Conduit and Cable Connections

3–6

Mounting Bracket

3–8

Power Requirements

3–12

Power Supplies

3–12

Power Connections

3–14

DeviceNet Connections

3–16

RS-485/RS-422 Connections

3–17

RS-232 Connections

3–18

I/O Modules and Wiring

3–19

Package Detector

3–22

Before mounting the wiring base, determine the proper orientation
and position as described in Chapter 2.

Leave adequate clearances for wiring.

The wiring base has four conduit openings. Seal unused conduit
openings with the 3 hole plugs provided with wiring base. Use
cord grips with rubber grommets on cables that enter wiring base.
Two different size grommets are provided with each cord grip.

Route wires carefully to reduce or minimize electrical noise.
When communication and power wiring must cross, make their
intersection perpendicular.

Proper grounding of the wiring base limits the effects of noise
due to Electromagnetic Interference (EMI). The wiring base has
a ground screw for connecting cable shields and ground wires. To
avoid EMI problems, all cables must be shielded and grounded at
one end. Grounding is also an important safety measure.

Wiring Base

Connect to
Earth Ground

Chapter Objectives

General Mounting
Guidelines

Advertising