Communication options – Rockwell Automation 2755 AdaptaScan Bar Code Readers User Manual

Page 19

Advertising
background image

Overview

1–11

This section defines the communication options for the Reader.

DeviceNet Network

AdaptaScan Readers support both DeviceNet Master/Slave and
Peer-to-Peer protocols.

On a DeviceNet Master/Slave network, Readers and other DeviceNet
slave devices communicate with a DeviceNet Scanner (Master). Up
to 63 slave devices are allowed on a master/slave network.

On a DeviceNet peer-to-peer network, up to 32 Readers can be
connected together. These Readers can:

work in a coordinated mode to read multiple bar code symbols on
different sides of the same package.

combine data from several Readers to a single Reader that
communicates the data to a host.

pass input and output status information between Readers.

Reader

Reader

Other

PLC-5 with 1771-SDN (DeviceNet Scanner)

DeviceNet Devices

AdaptaScan Bar Code Readers operate on a DeviceNet network at
the following baud rates (Kbps = Kilobits per Second):

Baud Rate

Supports Maximum Cable Length of:

125 Kbps

1640 feet (500 meters)

250 Kbps

656 feet (200 meters)

500 Kbps

328 feet (100 meters)