26

Industrial 19" CRT Monitor

Publication 6157-UM001A-EN-P

Status LEDs

The 6157- C Industrial Monitor has two status LED indicators on the
keypad. The following table lists the functions assigned to the LEDs:

Table C
6157- C Industrial Monitor Status LED Indicators

LED

Description

Power LED (Green)

Indicates that power is applied to the monitor.

Status LED (Amber)

Indicates that the monitor is not receiving a video
signal.

Note:

For information on troubleshooting the 6157- C Industrial
Monitor, refer to Page 40.

Auto Degauss

Degauss is automatically activated when the display has been powered
off for at least 20 minutes and power is applied.

Auto Registration

If adjustments have been made, the new settings are saved after ten
seconds of inactivity when the display automatically closes the windows.