CĆ2

Programming Terminal End of Cable

9ĆPin Female Connector

SIGNAL

PIN#

RECV

ă2

XMIT

ă3

CTS

ă8

RTS

ă7

DTR

ă4

DSR

ă6

COM

ă5

Reliance End of Cable

25ĆPin MaleConnector

PIN#

SIGNAL

ă2

XMIT

ă3

RECV

ă4

RTS

ă5

CTS

ă6

DSR

20

DTR

ă7

COM

Figure2

User Serial Ports

All AutoMax Processor module ports except for the port labeled

PROGRAMMER/PORT B" on theleftmost Processor in therack areavailableto

the user to connect to an external device which will be controlled by application

tasks running on the Processor. Refer to the Enhanced BASIC Language

Instruction Manual (JĆ3675) for moreinformation. Notethat with AutoMax

Processor modules, you can use the statements OPEN PORTA or OPEN PORTB.
Note: if you do not enable bit 15 (hardware handshaking) in the SETUP parameter of

the OPEN statement, only pins 2, 3, and 7 of the port you OPEN will be meaningful.
Pin# I/O

Function

2

O

This signal contains transmitted data.

3

I

This signal contains received data

4

O

Transmit status. This signal is true whenever the transmitter is sending

characters. It is used to bracket" a character transmission. It can be

used to enable/disable any type of external equipment, such as a

triĆstate transmit modem, which requires an enable signal to output

characters. Refer to the OPEN statement in the Enhanced BASIC

Language manual (JĆ3675) for details concerning the operation of the

modem enable signal (RTS pin on connector).

5

I

This signal enables the transmitter. It must be true for the transmitter to

send a character. This signal is typically used for hardware flow control.

It is meaningful only if hardware handshaking has been enabled.

6

I

This signal enables the receiver. It must be true in order for the receiver

to accept characters. If the signal becomes false while a message is

being received, any characters being received will be deleted and an

error will be reported to the application software. This signal is

meaningful only if hardware handshaking has been enabled.

7

Signal ground.

10

O

This signal is an isolated +12 Volt which can be used as an enable

or equipment ready indicator. The signal is always on whenever

power is applied to the Processor.

20

O

This signal indicates receiver status. The signal is true whenever the

receiver can accept characters, i.e., when the receive buffer is not

full. When the receive buffer fills to within a specified limit (53

characters), the signal is turned off. The signal can be used to

disable another transmitter. It is meaningful only when hardware

handshaking has been enabled.

Seethefollowing pagefor examples.