Rockwell Automation 47C626 AutoMax Programming Executive V4.2 User Manual
Page 55

5Ć21
Select Generate Log to create a log file that will list any errors that
may occur during the print job. Each section will have a separate log
file. The log file will exist under the system directory and will be
named _PRINT.LOG. If there are no errors, the log file will simply list
the files that were printed.
5.2.8
Transferring a Section
You can copy all the files for one or more selected AutoMax Executive
sections to diskettes (or another hard drive, or another library on the
same drive). You can copy all the files for an AutoMax Executive
section from diskettes (or a hard drive) into the current AutoMax
library (see section 5.1.8 for additional information). If you are
transferring to diskettes, you will need at least one diskette for each
rack in the section. You will be prompted for additional diskettes, if
needed. Diskettes can be formatted as needed or, to save time, you
can use blank preĆformatted diskettes. Use the following procedure
to transfer sections. Figure 5.14 illustrates the Transfer Section dialog
box.
Step 1.
Select the section(s) to be transferred from the Section list.
Step 2.
Select Transfer from the Section menu. The Transfer
dialog box will be displayed with the current AutoMax
Executive drive and library (as designated in AutoMax
Setup) listed in a box on the top left.
Step 3.
Enter information for the following fields. Some fields may
contain default entries. If you do not change these fields,
the default will be used.
Direction arrows Ć Transfer the section To (left arrow) or
From (right arrow) the current AutoMax Executive library.
Select the appropriate option button.
Drive Ć Enter the source drive or the destination drive. If A
or B is entered, the AutoMax Executive software assumes
the drive is a floppy drive; otherwise, AutoMax assumes a
hard drive.
Library Ć Enter the library directory to copy the section(s)
from or to.
Format Floppies Ć Select if you want to format destination
diskettes.
High Capacity Ć Select if you want to format and/or write to
high density diskettes. The appropriate diskette capacity
will be displayed.
Section(s) Ć The Executive software will list the sections(s)
selected when the Transfer command was called. If you
are transferring out of the current library and system,
make certain that this field lists all of the sections you have
selected. If you are transferring sections in, enter the
section names separated by commas or spaces.
Step 4.
Select which of the following groups of files you want to
transfer with each section:
Object files Ć compiled application tasks, parameter object
files, and rack configuration object files.
CrossĆreference files
Transfer Tokens (See Appendix N for more information.)