Mating cables, Commissioning, Required files – Rockwell Automation MPAR Electric Cylinders  User Manual

Page 20

Advertising
background image

20 MP-Series Electric Cylinders

Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012

Mating Cables

Commissioning

This section provides guidelines for using RSLogix™ 5000 software to configure your
electric-cylinder servo drive system.

Required Files

Firmware revisions and software versions required to support the electric cylinders include the
following:

Kinetix 2000 or Kinetix 6000 multi-axis drives

RSLogix 5000 software, version 16.00 or later

Firmware revision 1.96 or later

For RSLogix 5000 software, version 16.

xx,

use Motion Database file, version 4_23_0 or later

For RSLogix 5000 software, version 17.

xx or later,

use Motion Database file, version 5_15_0 or later

Kinetix 6200 multi-axis drives

Firmware revision 1.30 or later

For RSLogix 5000 software, version 17.

xx,

use MPAR_5_19_11.cmf or later

Kinetix 6500 multi-axis drives

Firmware revision 1.11 or later

For RSLogix 5000 software, version 18.

xx,

use MPAR_5_19_11.cmf or later

Kinetix 300 single-axis drives

For RSLogix 5000 software, version 17.xx or later

Connector

Cable Type

Cable Cat. No.

Feedback

Premolded

2090-CFBM7DD-CEAAxx (standard) or
2090-CFBM7DD-CEAFxx (continuous-flex)

Flying lead

2090-CFBM7DF-CEAAxx (standard) or
2090-CFBM7DF-CEAFxx (continuous-flex)

Power

With brake wires

2090-CPBM7DF-xxAAxx (standard) or
2090-CPBM7DF-xxAFxx (continuous-flex)

Without brake wires

2090-CPWM7DF-xxAAxx (standard) or
2090-CPWM7DF-xxAFxx (continuous-flex)

Advertising