Rockwell Automation MPAR Electric Cylinders  User Manual

Page 33

Advertising
background image

MP-Series Electric Cylinders 33

Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012

11.

Enter values from the following table.

These values are recommended; your application may require different values.

12.

Select recommend homing method ID = 33, Home to marker, Reverse.

13.

Set overtravel limits according to the maximum speed of the servo drive system and the
payload of the application.

Parameter

Metric

English

Home Accel/Decel

10.0000 mm/s

2

0.3937 in/s

2

Home Offset

0.0000 mm

0.0000 in.

Home Velocity Fast

10.0000 mm/s

0.3937 in/s

Home Velocity Slow

10.0000 mm/s

0.3937 in/s

Home Switch

Input B1

IMPORTANT

Set travel limits and direction of tuning moves in reference to piston rod starting
position. Leave adequate travel for the piston rod to complete its moves while
tuning.

ATTENTION: Software overtravel must be set prior to initiating the tuning process.
Check the starting position of the piston rod and allow for adequate travel.
Insufficient travel while auto tuning will cause the software overtravel to trigger an
end-stop impact.

ATTENTION: Care should be taken to not exceed the physical travel limits of the electric
cylinder. Doing so will cause the electric cylinder to reach the mechanical end-of-stroke.
Impacting the mechanical end-of-stroke can physically damage the screw and internal
components of the electric cylinder.

Advertising