MP-Series Electric Cylinders 21

Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012

use Kinetix 300 drive MotionView OnBoard web interface

Kinetix 350 single-axis Ethernet drives

RSLogix 5000 software, version 20.xx or later

Firmware revision 1.30 or later

Ultra™ 3000 drives

Firmware revision 1.52 or later

Motion Database (.mdb) file, dated April 2010 or later

Motion Analyzer software, version 4.7 or later

Download these files from

http://www.rockwellautomation.com/support

. Contact Rockwell

Automation Technical Support at (440) 646-5800 for assistance.

Configure Your Electric Cylinder

Configure the electric-cylinder by using the basic parameter settings described in this section.
Use the procedure appropriate for your motion axis.

Drive

Refer to:

Kinetix 350
Kinetix 2000
Kinetix 6000
Kinetix 6200
Kinetix 6500

Configure Your Electric Cylinder with RSLogix 5000 Software

immediately below, and

Tune Your Electric

Cylinder with RSLogix 5000 Software

on

page 27

.

Ultra3000

Configure Your Electric Cylinders with Ultraware Software

on

page 30

.

Kinetix 300

Configure the Kinetix 300 Drive for Electric Cylinders

on

page 32

ATTENTION: Moving parts can cause injuries. Before running the electric cylinder, make sure all
components are secure and safeguards are in place to prevent access to the path of moving
machinery.
Safeguards should prevent access to the electric cylinder until all motion has stopped.
Check that the electric cylinder is clear of foreign matter and tools. Objects hit by the moving
piston rod can become projectiles that can cause personal injury or damage to the equipment.

IMPORTANT

It is your responsibility to verify that the servo control system safely controls the electric
cylinder with regard to maximum force, acceleration, and speed.