42 MP-Series Electric Cylinders
Rockwell Automation Publication MPAR-IN001D-EN-P - September 2012
Specifications
Brake Specifications
Environmental Specifications
Electric
Cylinder
Cat. No.
Holding
Force
N (lb)
Coil Current
at 24V DC
A
Brake Response Time
Release
(1)
ms
(1)
Brake release time delay with voltage applied.
Engage (using external
arc-suppression device)
MOV
(2)
ms
(2)
Brake engage time delay with voltage removed and MOV used for arc suppression.
Diode
(3)
ms
(3)
Brake engage time delay with voltage removed and diode used for arc suppression.
MPAR-A/B1xxxB
300 (67)
0.43…0.53
23
9
18
MPAR-A/B1xxxE
350 (79)
MPAR-A/B2xxxC
525 (118)
MPAR-A/B2xxxF
800 (180)
0.46…0.56
58
20
42
MPAR-A/B3xxxE
2364 (531)
0.45…0.55
50
20
110
MPAR-A/B3xxxH
1625 (365)
0.576…0.704
110
25
160
Attribute
Value
Temperature, ambient
0…40 °C (32…104 °F)
Temperature, atorage
-25…60 °C (-13…140 °F)
Relative humidity (noncondensing)
5…95%
Shock
20 g peak, 6 ms duration
Vibration
2.5 g peak @ 30…2000 Hz