Operation mode: Protective operation (see M7961)

e.g. light curtains to secure dangerous areas
 Connection up to 3 light curtains

 Manual or automatic start possible for each light curtain

 With or without feedback input for external contactors

Possible settings:

M7942

Automatic start
On automatic start the contacts K1 and K2 are energized when the light

curtain that is set for auto start is free after interruption. It is necessary that
the other light curtains with manual start are not interruped.

Manual start

On manual start the contacts K1 and K2 are energized when the light barrier
that is set for manual start is free after interruption and the start button is
pressed.

The start button must be activated in 2 conditions:
-

After return of the supply voltage

(when minimum 1 light curtain is programmed for manual start)

-

When 1 light curtain with manual start was interrupted

Switch 10: Start mode and feedback input

0

1

2

3

4

5

6

7

8

9

without feedback

input

with feedback input

S

wit

ch 1

0 LC 1

LC 2
LC 3

Auto
Manu
Manu

Auto
Auto
Manu

Auto
Auto
Auto

not

allowed

(fault 5)

Auto
Manu
Manu

Auto
Auto
Manu

Auto
Auto
Auto

not

allowed

(fault 5)

1 LC 1

LC 2
LC 3

Manu
Manu
Manu

Manu
Auto
Manu

Manu
Auto
Auto

Manu
Manu
Manu

Manu
Auto
Manu

Manu
Auto
Auto

Function diagram