Rockwell Automation 440R Lichtgittermodul MSR22LM mit umschaltbaren Funktionen Light curtain controller User Manual

Page 15

Advertising
background image

15

Technical

Data

Input

Nominal voltage U

N

: DC

24

V

Voltage range:
at max. 5 % residual ripple:

0,85 ... 1,15 U

N

Nominal consumption:

max. 170 mA

(no load on semiconductor outputs)

Control voltage on
S21, S23, S31, S33, S41,
S43, S48, S58:

DC 23 V at U

N

Control current on
S12, S14, S22, S24,
S32, S34, S42, S44:

each 4,5 mA at U

N

Min. voltage on terminals
S12, S14, S22, S24, S32,
S34 S42, S44:
DC

16

V

Short circuit protection:

internal with PTC

Min. current on M1, M2:

25 mA with active lamp

Output

Contacts
MSR22LM.03:

3 NO contacts

MSR22LM.22:

2 NO, 1 NC contacts

The NC contact must only be used as

monitoring contact !

Contact type:

Relay, positive guided

Operate delay typ. at U

N

:

Manual start:

max. 50 ms

Automatic start:

max. 1,5 s

Automatic restart:

max. 55 ms

Release delay (reaction time):

max. 30 ms

(max. 50 ms when failure on LC and

only one input channel de-energises)

Output voltage: AC

250

V

DC: see Limit curve for arc-free

operation*

)

*

)

see datasheet MSR22LM on www.rockwellautomation.com

Switching of low loads:

 100 mV

Thermal current I

th

: 5

A

Switching capacity
to AC 15:
NO contact:

3 A / AC 230 V

IEC/EN 60 947-5-1

NC contact

2 A / AC 230 V

IEC/EN 60 947-5-1

to DC 13 at 0,1 Hz:

8 A / DC 24 V

IEC/EN 60 947-5-1

Electrical life
to AC 15 at 2 A, AC 230 V:

10

5

switching cycles

IEC/EN 60 947-5-1

Permissible switching
frequency:

max. 1 200 switching cycles / h

Short circuit strength
max. fuse rating:

6 A gL

IEC/EN 60 947-5-1

line circuit breaker:

C 8 A

Semiconductor outputs

Output (terminal 48 and 58):

Transistors, plus-switching

Output voltage:

DC 24 V,

max. 100 mA continuous current,

max. 400 mA for 0,5 s internal short

circuit, overtemperature and overload

protection

General Data

Operating mode: Continuous

operation

Temperature range
operation:

 0 ... + 50 C

storage :

- 25 ... + 85

C

altitude:

< 2.000 m

Clearance and creepage
distances
rated impuls voltage /
pollution degree:

4 kV / 2 (basis insulation)

IEC 60664-1

EMC
Electrostatic discharge:

8 kV (contact)

IEC/EN 61 000-4-2

(according to test degree 3)

HF irradiation:

10 V / m

IEC/EN 61 000-4-3

Fast transients:
on wires for power supply A1-A2: 2

kV

IEC/EN 61 000-4-4

on wires for signals and control:

2 kV

IEC/EN 61 000-4-4

Technical

Data

Surge voltages
between
wires for power supply:

1 kV

IEC/EN 61 000-4-5

between wire and ground:

2 kV

IEC/EN 61 000-4-5

HF wire guided:

10 V

IEC/EN 61 000-4-6

Interference suppression:

Limit value class B

EN 55 011

Degree of protection:

according to IEC/EN 61 496-1 (1997)

the unit has to be installed in a housing

with protection degree 54.

Housing:

IP 40

IEC/EN 60 529

Terminals:

IP 20

IEC/EN 60 529

Housing:

Thermoplastic with V0 behaviour

according to UL subject 94

Vibration resistance:

according to IEC/EN 61 496-1 (1997)

Amplitude 0,35 mm

IEC/EN 60 068-2-6

frequency 10 ... 55 Hz

Shock resistance:
Acceleration: 10

g

Impulse length:

16 ms

Number of shocks:

1000 per axis on 3 axis

Climate resistance:

0 / 050 / 04 IEC/EN 60 068-1

Terminal designation:

EN 50 005

Wire fi xing:

Terminal screws M 3,5

Box terminal with wire protection

Mounting:

DIN rail

IEC/EN 60 715

Weight: 320

g

UL-Daten

The safety functions were not evaluated by UL. Listing is a
ccomplished according to requirements of Standard UL 508, “general
use applications”.

Nominal voltage U

N

:

DC 24 V

Ambient temperature:

0 … +50°C

Switching capacity:
Ambient temperature 50°C:

Pilot duty B300

5A 250Vac G.P.

5A 24Vdc

Semiconductor outputs:

24Vdc, 100 mA

Wire connection:

60°C / 75°C copper conductors only

AWG 20 - 12 Sol Torque 0.8 Nm

AWG 20 - 14 Str Torque 0.8 Nm

nfo

Technical data that is not stated in the UL-Data, can be found
in the technical data section.

Advertising