Installing the Rear Clevis Mounting Kit

Follow this procedure to install a rear clevis mount on an MP-Series electric cylinder.

1. Prepare a contamination-free area in which to work.
2. Remove the four bolts that secure the end cap.

Bolts sizes are shown here.

3. Set aside the mounting bolts for reuse.
4. Clean the mounting surface and verify it is undamaged before continuing.
5. Carefully position the rear clevis mount and seal on the mounting surface.

The seal is included in the rear clevis mounting kit.

6. Using an alternating torque pattern, evenly torque each of the four mounting bolts to

value shown on

page 10

.

ATTENTION: Proper attachment of the rear clevis mount is important to achieving an IP67 rating.
Failure to observe this procedure could result in damage to the electric cylinder and its
components.

Frame Size

Bolt Size

64

M6 x 1.0 (0.04)

83

M8 x 1.25 (0.05)

110

144

M12 x 1.75 (0.07)