32 MP-Series Heavy Duty Electric Cylinders

Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012

1. Enter these parameters in the Axis Properties tab of RSLogix 5000 software for your

electric cylinder.

Axis Properties

Tab

Parameter

Entry/Selection

Drive/Motor

Motor Catalog Number

Choose one from the

pull-down menu.

MPAI-A2xxxCV1xx

MPAI-A2xxxCV3xx

MPAI-A3xxxCM1xx

MPAI-A3xxxEM1xx

MPAI-A3xxxRM1xx

MPAI-A3xxxSM1xx

MPAI-A3xxxCM3xx

MPAI-A3xxxEM3xx

MPAI-A3xxxRM3xx

MPAI-A3xxxSM3xx

MPAI-A4xxxCM3xx

MPAI-A4xxxEM3xx

MPAI-A4xxxRM3xx

MPAI-A4xxxSM3xx

MPAI-A5xxxCM3xx

MPAI-A5xxxEM3xx

MPAI-B2xxxCV1xx

MPAI-B2xxxCV3xx

MPAI-B3xxxCM1xx

MPAI-B3xxxEM1xx

MPAI-B3xxxRM1xx

MPAI-B3xxxSM1xx

MPAI-B3xxxCM3xx

MPAI-B3xxxEM3xx

MPAI-B3xxxRM3xx

MPAI-B3xxxSM3xx

MPAI-B4xxxCM3xx

MPAI-B4xxxEM3xx

MPAI-B4xxxRM3xx

MPAI-B4xxxSM3xx

MPAI-B5xxxCM3xx

MPAI-B5xxxEM3xx

Drive Resolution

200,000

Drive Counts per

Motor Rev

Conversion

Positioning Mode

Linear

Setting the Positioning Mode to Rotary can cause damage to

the electric cylinder or the machine due to incorrect

positioning.

Conversion Constant

20,000 drive cnts/1.0 mm

for

508,000 drive cnts/1.0 in. for

MPAI-x3xxxEM1xx

MPAI-x3xxxEM3xx

MPAI-x3xxxSM1xx

MPAI-x3xxxSM3xx

MPAI-x4xxxEM3xx

MPAI-x4xxxSM3xx

MPAI-x5xxxEM3xx

Conversion Constant

40,000 drive cnts/1.0 mm

for

1,016,000 drive cnts/1.0 in. for

MPAI-x2xxxCM1xx

MPAI-x2xxxCM3xx

MPAI-x3xxxCM1xx

MPAI-x3xxxCM3xx

MPAI-x3xxxRM1xx

MPAI-x3xxxRM3xx

MPAI-x4xxxCM3xx

MPAI-x4xxxRM3xx

MPAI-x5xxxCM3xx

Advertising