52 MP-Series Heavy Duty Electric Cylinders

Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012

Electric cylinder is operating but is not

up to rated speeds/forces.

Motor phases are wired incorrectly

or in incorrect order.

Verify correct motor power wiring.

Amplifier may be improperly tuned.

Verify gain settings.

Amplifier may be set up improperly

for electric cylinder used.

Verify amplifier setting for number of poles,

voltage, current, resistance, inductance,

inertia, and other motor settings.

Electric cylinder cannot move load.

Force is too large for the capacity of

the electric cylinder or too much

friction is present.

Verify force requirements.

Misalignment of thrust rod to load.

Verify load alignment.

Amplifier has too low of current

capacity or is limited to too low of

current capacity.

Verify correct amplifier and settings.

Electric cylinder moves or vibrates

when thrust rod is in motion.

Loose mounting.

Verify actuator mounting.

Amplifier is improperly tuned or

gain setting is wrong.

Tune amplifier.

Actuator is overheating.

Duty cycle is higher than actuator

rating.

Verify load forces and electric cylinder rating.

Actuator operated outside of

continuous rating.

Adjust operation to be within continuous

operation rating.

Amplifier is poorly tuned, requiring

excessive current be applied to the

motor.

Verify gain settings.

Troubleshooting Electric Cylinders (cont.)

Description

Possible cause

Corrective action