Tune Your Electric Cylinder with RSLogix 5000 Software

This section shows the steps to tune electric cylinders with RSLogix 5000 software. Refer

to Required Files on

page 30

for the version number:

Tuning your electric cylinder requires you to calculate and configure the loop gain based
on the actual measured inertia.

By setting travel limits, your application minimum deceleration is defined.

Maximum acceleration is determined automatically during the tuning process.

Follow these steps to tune your electric cylinder.

1. In the Axis Properties dialog box, click the Fault Actions tab.
2. Click Set Custom Stop Action.

3. In the Custom Stop Action Attributes dialog box, set the Brake Engage and the Brake

Release delay times to the values listed in

Specifications

on

page 65

.

4. Reduce the default Stopping Time Limit from 10 seconds to 0.5 seconds.

TIP

These parameter settings work best if the electric cylinder is installed in a horizontal
(table top) or a wall mount (vertical) orientation.

IMPORTANT

To prevent the rod from moving or falling when installed in a vertical orientation,
the Stopping Time Limit must be set to 0.99 seconds or less.