MP-Series Heavy Duty Electric Cylinders 15

Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012

Hand tighten the collar of a SpeedTec (M7) connector one-quarter turn.

3. Form a drip loop in the cable to keep liquids away from the connectors.
4. Verify the continuity and functionality of the thermal switch signals, TS+ and TS-.

These signals are transmitted through the feedback cable that connects the motor to its

controlling drive.

ATTENTION: Make sure cables are installed and restrained to prevent uneven tension or
flexing at the cable connectors. Excessive and uneven lateral force at the cable
connectors may result in the connector’s environmental seal opening and closing as the
cable flexes.
Failure to observe these safety precautions could result in damage to the electric cylinder
motor and its components.

Flat Surface

with Logo on Top

Top of connector is relative to motor

orientation.

Feedback Connector

Drip Loop

Power Connector

Flat Surface

with Logo on Top