Configure Your Kinetix 300 Servo Drive with MotionView OnBoard
Use this procedure to configure your Bulletin MPAI electric cylinder with a Kinetix 300 servo
drive. Refer to the Kinetix 300 EtherNet/IP Indexing Servo Drive User Manual,
publication
for details on using the MotionView OnBoard software.
These steps assume an electric cylinder and Kinetix 300 drive are installed and wired as one axis
of a motion system.
1. Establish a connection to the Kinetix 300 servo drive via MotionView OnBoard
software.
2. From the Drive Organizer, select Motor.
3. Click Change Motor.
The motor model will automatically update to the correct model number.
4. Click Yes twice.
5. Verify the motor model matches the electric cylinder model connected to the drive.
6. From the Drive Organizer, select General.
7. Set User Units by entering values for your model from this table.
8. Home the axis.
2097-UM001
, if you
need guidance.
Cat. No.
Lead mm/rev (in./rev)
Rev/unit
MPAI-xxxxCxxx, MPAS-xxxxRMxx
5.0 (0.197)
0.2
MPAI-xxxxEMxx, MPAS-xxxxSMxx
10.0 (0.394)
0.1