Catalog Number Explanation

This is the catalog explanation for the MPAI electric cylinders.

Special Feature

(1)

Blank = IP67 is standard

W = Food grade (white paint) stainless steel rod
Actuator Mounting

A = Front face, side front, bottom front and rear tapped mounting holes

B = Front trunnion, no tapped mounting holes

C = Rear clevis mount, no tapped mounting holes

(food-grade paint only)

E = Front face mount, front face tapped mounting holes

(food-grade paint only)

Holding Brake

2 = No brake
4 = 24V DC brake
Motor Type

1 = 76 mm (3 in.) stroke length
3 = 150…450 mm (6…18 in.) stroke length

Motor Feedback Type
M = Multi-turn, 1024 sin/cos, absolute encoder, Hiperface protocol

(2)

V = Multi-turn, 128 sin/cos, absolute encoder, Hiperface protocol
Mechanical Drive/Screw Lead, Motor Type

C = 5.0 mm/rev ball screw (0.197 in./rev)
E = 10.0 mm/rev ball screw (0.394 in./rev)

(2)

R = 5.0 mm/rev roller screw (0.197 in./rev)

(2)

S = 10.0 mm/rev roller screw (0.394 in./rev)

(2)

Rod Stroke Length
076 = 76.2 mm (3.0 in.)

(3)

150 = 152.4 mm (6.0 in.)

300 = 304.8 mm (12.0 in.)
450 = 457.2 mm (18.0 in.)

(2)

Actuator Frame Size

2 = 64 mm (2.52 in.)

3 = 83 mm (3.27 in.)

4 = 110 mm (4.33 in.)

5 = 144 mm (5.67 in.)
Voltage Class

A = 200V

B = 400V
Actuator Type

AI = Actuator rod
Actuator Series

MP-Series

(1) The Special Feature field is for customer specific coding.

(2) Not available in the 64 mm (2.25 in.) frame.

(3) 76 mm (3.0 in.) stroke length, is only available in the 64 mm (2.5 in.) and 83 mm (3.27 in.) frames.

MP AI - x x xxx x x x x x - x