Storage – Rockwell Automation MPAI Heavy Duty Electric Cylinders User Manual
Page 50
![background image](/manuals/581551/50/background.png)
50 MP-Series Heavy Duty Electric Cylinders
Rockwell Automation Publication MPAI-IN001E-EN-P - March 2012
Storage
Store your electric cylinder for a minimal amount of time in a clean and dry location within the
Environmental Specifications on
Observe these conditions when storing the electric cylinder:
•
Be sure the equipment is in good working order before storing. Perform repairs,
maintenance, and inspections before storing equipment.
•
Store the equipment in a suitable storage position (horizontal) that will prevent damage
to the connectors and electronics.
•
After 6 months of storage, cycle the equipment two complete strokes to redistribute the
internal lubricants.
•
After storage for a period longer than 2 years without use, lubricant replacement is
recommended through Rockwell Automation Technical Support.