SP200 AC Drive Quick Start Guide

Local Keypad Operation

1

In display mode, the UP ARROW key increments the local speed reference.
In program mode, this key increments the parameter number or parameter
value.

2

The PROGRAM key toggles between display and program modes. The
PROGRAM LED (5) turns on when the drive is in program mode.

3

In display mode, the ENTER key increments to the next display parameter.
In program mode, this key toggles between the parameter number and
parameter value.

4

The RUN LED turns on when the drive is running in either the foward or
reverse direction. The RUN LED flashes while the drive is changing
direction.

5

The PROGRAM LED turns on when the drive is in program mode.

6

In display mode, the DOWN ARROW key decrements the local speed
reference.
In program mode, this key decrements the parameter number or parameter
value.

7

The STOP key issues stop and fault reset commands to the drive.

8

The START key issues start commands to the drive when P-10 = 1.

9

The display shows either a parameter number or a parameter value.

The parameter numbers are preceded by either a “P-” or a “d-”.