Control Module Configuration

22

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Figure 5-9. Use the PSF Configuration screen to program each control module individually

Serial Transmission

Specifies the type of data transmitted

from the control module to its host

after each scan.

Measurement Mode Result: Data

transmitted will reflect the Analysis Mode

selections.

All Mode: Transmits all data.

Max. Meas. Mode: Sends only the largest

measurement in each measuring event, to

decrease transmission size and speed

response. Choose to send when the array

is clear or send at the host’s request.

Transmission Type: ASCII or Binary,

defines the format in which the data

will be sent.

Serial Options: Suppress Clear Data

or Suppress Header to decrease

transmission size and speed response.

Analysis (Measurement)

Mode Selection

Choose the measurement

option that best tells you

the size and/or position

of objects as they

relate to the array.

Control Mode Selection

Continuous Mode: The control

module constantly polls

the array for status.

Host Mode: The control module

polls the array for status when

prompted by a host controller.

Gate Mode: The control module

polls the array for status when

prompted by an input from a

Gate sensor.

Scanning Method

Straight scan polls each beam

sequentially to determine the target

object’s overall size. This is the most

accurate and precise measurement,

but also the most time-consuming.

Single Edge scan requires the target

object to block beam 1 (closest to

the sensors’ cabled ends), then

conducts a time-saving binary

search to “hunt” for the target’s

overall height (one variable edge).

Double Edge scan conducts a

time-saving search of the entire

array to “hunt” for the target’s

overall width (two variable edges).

Set Point and

Hysteresis Selection

Assigns the set point to

determine where within the

array the output(s) will

respond and hysteresis

values to smooth output

response.

Trigger/Trigger Channel Number

May be used to trigger (or gate) the scan sequence of another

A-GAGE High-Resolution MINI-ARRAY controller; in straight scanning

mode, it defines when during each scan discrete Output #2 will change

state.

Scan #:

(1-9) Analog outputs are

updated with an average value of the

data received during the selected

number of scans; discrete outputs

respond only if the received data is

identical for all of the selected number of

consecutive scans.

Analog and Discrete

Output Assignment

Assigns an analysis

(measurement) mode

to each output.

Alarm: Causes the control module to

turn on discrete Output #2 whenever

the System detects a sensing error or

if the optical signal becomes marginal.

Selected Controller

Identifies the specific

control module being

configured.

Serial Communication

Changes the identification

and baud rate of the

controller being

configured.

Zero Value

Zero Value is used to specify the

analog output when the

measurement mode value is zero.

The user can specify a value

of LAST, NULL, or SPAN.

LAST:

Output holds the last non-zero value before the

light screen became clear.

NULL: Provides the minimum value.

SPAN:

Provides the maximum value.