Environmental Rating

Minimum Object Sensitivity

2.5 mm (0.1")

NEMA 4, 13 (IP65)

Sensor Scan Time

1.8 milliseconds to 58.4 milliseconds, depending on scanning method and sensor length; see Section

5.3.3 for detailed information

Power Requirements

12V dc ±2%, supplied by controller

Status Indicators

Emitter: Red LED lights to indicate proper emitter operation

Receiver: Green indicates sensors aligned

Yellow indicates marginal alignment of one or more beams

Red indicates sensors misaligned or one or more beam(s) blocked

Connections

Sensors connect to controller using two 5-conductor quick-disconnect cables (one each for emitter and

receiver), ordered separately. See page 5 for available lengths. Use only Banner cables, which incorporate

a “twisted pair” for noise immunity. Cables measure 8.1 mm (0.32") in diameter and are shielded and

PVC-jacketed. Conductors are 20 gauge (0.9 mm). Emitter and receiver cables may not exceed 75 m

(250') long, each.

Construction

Aluminum, with black anodized finish; acrylic lens cover

Operating Conditions

Temperature: 0° to +50°C (+32° to 122°F)

Maximum relative humidity: 95% at 50°C (non-condensing)

Emitter/Receiver Range

380 mm to 1.8 m (15" to 6')