2 system features, System description, Banner engineering corp – Banner A-GAGE High-Resolution MINI-ARRAY Series User Manual

Page 6: Minneapolis, u.s.a

Advertising
background image

P/N 64118 rev. B

System Description

6

Figure 1-2. A-GAGE High-Resolution MINI-ARRAY System features

1.2 System Features

Built-in features simplify the operation of the A-GAGE High-Resolution MINI-ARRAY

system. High-resolution emitters and receivers, available in 12 lengths, feature two

closely spaced columns of beams to provide a precise, high-resolution light screen for

exacting applications. The Alignment routine automatically equalizes the excess gain of

each beam for reliable 2.5-mm (0.10") object detection throughout the array and stores

this data in non-volatile memory. The Alignment routine need not be performed again

unless the sensing application changes, or if the emitter and/or receiver is moved.

Programmable beam blanking accommodates machine components or other fixtures that

must remain in or move through the light screen. Blanking may be set automatically as

part of the initial setup, or by using the included configuration software.

Built-in diagnostic programming and easy-to-see indicators on the sensors and the

control module make alignment and troubleshooting easy (Figure 1-2). The emitter has

a red LED that signals proper operation. The receiver has three bright LEDs: green

signals that the sensors are properly aligned; yellow signals marginal alignment; and

red signals misalignment or a blocked condition. The control module has four status

indicators: 3 red LEDs signal discrete output #1 conducting (see section 5.3.5 for more

information on outputs), Alarm output (discrete output #2) conducting, and gate signal

received; a green LED signals that the sensors are properly aligned. A segmented LED

Diagnostics Indicator provides detailed system status using single-digit codes; a

“period” in the indicator window indicates the presence of blanking. A key to the

diagnostics codes is printed on the side of the control module for simplified

troubleshooting.

The A-GAGE High-Resolution MINI-ARRAY System provides a wide selection of

sensing and output options, including: measurement (“scan analysis”) modes and

scanning methods that can determine the target object’s location, overall size, total

height or total width. Scanning may be continuous or controlled by a host process

controller or a gate sensor. Up to 15 systems may be networked.

High-Resolution Emitter

DIN-Rail-Mountable Control Module

High-Resolution Receiver

HIGH RESOLUTION MINI-ARRAY CONTROLLER

ALIGNMENT

SWITCH

POWER

POWER

DIAGNOSTICS

INDICATOR

2 - TX

3 - RX

5 - COM

RS-232

MAHCVP-1

OUTPUT

ALARM

GA

TE

ALIGN

1

+

+

16-30V dc

1A MAX

10-30VDC

GATE

D OUT 1

150mA MAX

0-10VOLTS

25mA (MAX)

V OUT 1

EMTR

RCVR

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16 17 18 19 20

F1

+12V COM DRN T/R T/R

BR BU

BK WH

TX TX

+

10-30VDC

ALIGN

0-10VOLTS

25mA (MAX)

V OUT 2

+V

ALARM

150mA MAX

+V

7.6 mm (0.30")

2.5 mm

(0.10")

5.1 mm

(0.20")

Diagnostics Indicator

Alignment Button

Red Discrete Output #1 LED

Red

Operational

LED

Green Alignment LED

Red Blocked LED

Yellow Marginal

Alignment LED

Red Alarm (Discrete Output #2) LED

Red Gate LED

Green Align LED

RS-232 Port

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Advertising