FIBER OPTIC Mode

glass fiber optics

Range: see excess gain curves
Temp. range: -40 to +100 degrees C

Fiber optic information:
IT13S: individual assembly
.06 in. (1,5mm) dia. bundle
IT23S: individual assembly
.12 in. (3mm) dia. bundle
BT13S:bifurcated assembly
.06 in. (1,5mm) dia. bundle
BT23S:bifurcated assembly
.12 in. (3mm) dia. bundle
L9: .5 in. (12mm) dia. lens
L16F: 1.0 in. (25mm) dia.
lens

Models/Dimensions

Sensors are epoxy-encapsulated and optics are hermetically sealed. Cables are 6 feet (2m) long. 30-foot (9m) cables available by special order.
Sensor accessories are shown on page 24.

FOF-400 Fiber optic Fitting

Hookup of LR/PT200, 250, 300, and 400

6

0

0

I
N
C
H
E
S

30

1

2

3

1

2

3

24

12

18

OPPOSED DISTANCE--INCHES

Opposed mode

w/IT13S fibers

w/IT23S fibers

LR/PT400

15

0

0

I
N
C
H
E
S

OPPOSED DISTANCE--FEET

30

45

75

8

16

24

8

16

24

60

Opposed mode

IT23S fibers and
L16F lenses

LR/PT400

IT23S fibers and
L9 lenses

5

0

0

I
N
C
H
E
S

25

3

6

9

3

6

9

20

10

15

w/L9 lens

w/L16F lens

DISTANCE TO REFLECTOR--FEET

Retroreflective mode,
with BRT-3 reflector and
BT13S fiber

LR/PT400

1

0

0

I
N
C
H
E
S

5

4

2

3

DISTANCE TO 90% WHITE TEST CARD--INCHES

Diffuse mode

w/BT13S fibers

w/BT23S fibers

0.2

0.4

0.6

0.6

0.4

0.2

LR/PT400

10

1

DISTANCE

100

1000

.1 IN

1 IN

10 IN

100 IN

Diffuse mode -- range based on
90% reflectance white
test card

with
BP13S
fibers

with
BT23S
fibers

E
X
C
E
S
S

G
A
I
N

I

LR/PT400

Beam Pattern

Excess Gain

10

1

DISTANCE

100

1000

.1 IN

1 IN

10 IN

100 IN

with IT23S
fibers

with IT13S
fibers

Opposed mode,
no lenses

E
X
C
E
S
S

G
A
I
N

I

LR/PT400

10

1

DISTANCE

100

1000

.1 FT

1 FT

10 FT

100 FT

Retroreflective mode, with
BT13S fibers

with L16F
lens
and BRT-3
reflector

with L9 lens
and BRT-3
reflector

E
X
C
E
S
S

G
A
I
N

I

LR/PT400

10

1

DISTANCE

100

1000

.1 FT

1 FT

10 FT

100 FT

Opposed mode,
with IT23S
fibers

with
L16F
lenses

with
L9
lenses

E
X
C
E
S
S

G
A
I
N

I

LR/PT400

MAXI-AMP System

Sensors for use with CM Series Modulated Amplifiers

16

LR400 & PT400

with FOF-400 fittings and
fiber optics

For complete information on glass
fiber optic assemblies and acces-
sories, see Banner product catalog.

Hookup

to CM Series

MAXI-AMP

Modules

The hookup diagrams on this page and the
next include all of the remote sensors for use
with CM Series modulated amplifier mod-
ules.
It is important to note how the shield wire
of a remote sensor is wired. The shield wire is the
uninsulated wire in each sensor cable. Failure to
connect the shield as shown may result in false
operation of the amplifier. When wiring emit-
ters, it is good practice to connect the positive
(white) wire first. LEDs are sensitive to applica-
tion of the wrong voltage, and can easily be
destroyed.

NOTE: up to three sensors may be connected to
each amplifier (see specifications).

The threaded barrel design of the
LR400 and PT400 (see page 14) per-
mit the connection of any Banner
glass fiber optic assembly by using
two model FOF-400 fittings. The
sensors are typically mounted
through 3/8 inch (10mm) diameter
clearance holes, with the FOF-400
fittings threaded onto them after
mounting. Setscrews in the fittings
lock the fibers in place, but allow
rapid replacement without disturb-
ing any electrical wiring.

As the excess gain curves show, the
LR/PT400 combination produces a
high-performance fiber optic sens-
ing system. With the amplifier's 1
millisecond response time, this sys-
tem can be used for almost any fiber-
optic requirement.