Maxi-amp, System, Sp12 series – Banner MAXI-AMP Series User Manual

Page 7: Specifications, sp12 sensors, Sp12 series barrel sensors

Advertising
background image

SP12 Series

Opposed Mode Remote Modulated Barrel Sensors

for use with MAXI-AMP CD Series Modules

Model

Type

Housing Material

SP12SEL

SP12PEL

SP12SRL

SP12PRL

Emitter

Emitter

Receiver

Receiver

Stainless steel

VALOX

®

Stainless steel

VALOX

®

NOTE: Models with 30-foot attached cable are available (contact factory
for information).

2- and 3-conductor 50- and 100-foot extension cables

(without connectors) are also available. For 2-conductor (emitter) cable:
order model EC12E-50 (50') or model EC12E-100 (100'). For 3-conductor
(receiver) cable: order model EC12R-50 (50') or model EC12R-100 (100').

SP12 Series Barrel Sensors

VALOX

®

is a registered trademark of General Electric Co.

10

0

DISTANCE

100

1000

1 FT

SP12 Series
opposed mode
emitters and
receivers

10 FT

100 FT

1000FT

E
X
C
E
S
S

G
A
I
N

I

15ms
response

1.5ms
response

Beam Pattern

Excess Gain Curve

40

0

0

I
N
C
H
E
S

OPPOSED DISTANCE--FEET

80

120

160

200

20

40

60

20

40

60

SP12 Series emitters
and receivers

1.5ms response

15ms response

Banner SP12 Series sensors are a family of powerful, modulated,
totally-encapsulated opposed mode remote sensor pairs in compact,
threaded-barrel type housings. They are the ideal choice for applica-
tions that require high excess gain together with small size in difficult
sensing environments. SP12 Series sensors are especially effective at
penetrating heavy contaminants when used at close range.

The preamplified design of these sensors results in exceptional noise
immunity. Signals carried along remote receiver cables are often
subject to interference (from electrical noise sources) that can be as
strong as (or stronger than) the desired light signal. The severity of this
problem often worsens with increasing sensor cable length. SP12
Series receivers contain a preamplifier that immediately boosts the
received light signal to a high level before sending it down the cable to
the rest of the sensing system.

SP12 Series sensors are designed for use with the Banner CD Series
MAXI-AMP™ modules. CD Series modules provide sensor power,
additional amplification, a choice of several programmable timing
logic functions (CD5 models), and output circuitry for interfacing to
a load. They also allow two different programmable sensor modulation
frequencies, making it possible to use multiple high-powered sensor
pairs in close proximity to each other without optical crosstalk. CD
Series modules are available for a wide range of supply voltages. Each
CD module powers one SP12 emitter/receiver pair. See page 3 for more
information.

SP12 sensors are rated NEMA 6P (IEC IP67) for use in wet locations.
There is a choice of either VALOX

®

or stainless steel housing style (see

table, below). Positive sealing at both ends of the sensors, with no
exposed epoxy interfaces, eliminates all leak paths (including capillary
leakage). Electronics are fully encapsulated for maximum resistance to
mechanical shock and vibration. Lenses are acrylic, and quad-ring
sealed. These sensors may be used with watertight, thread-on aper-
tures to create very narrow, very powerful effective beams (see next
page).

A 1/2" clearance hole is required for mounting. Alternatively, the
Banner model SMB12MM mounting bracket may be used (see next
page). SP12 Series sensors are supplied with 6-1/2 feet of PVC-
covered attached cable, or QD connectors (page 8). Options for models
with attached cable are summarized below. The maximum recom-
mended emitter or receiver cable length is 100 feet (each).

Leakproof NEMA 6P threaded-barrel opposed mode
remote sensor pairs; VALOX

®

or stainless steel housing

Compact and powerful: 1/2" (12mm) in diameter by 2"
long; 200-foot sensing range. Apertures are available.

Special preamplified circuit design for noise immunity
equal to that of self-contained sensors

SUPPLY VOLTAGE:

sensors are powered from a Banner CD Series

MAXI-AMP™ module (see page 3).

RANGE:

up to 200 feet in opposed mode (see gain curve, above).

RESPONSE SPEED:

selectable for 1.5 or 15 milliseconds; a function

of the MAXI-AMP CD Series module.

LIGHT BEAM:

infrared LED, 880nm. Effective beam diameter: 3/8".

CONSTRUCTION:

NEMA 6P.

12mm diameter tubular threaded VALOX

®

or stainless steel housing;

positive sealing at both ends, quad-ring sealed acrylic lens. Electronics
fully epoxy-encapsulated. Two jam nuts are provided: VALOX

®

for

VALOX

®

units; stainless steel for stainless steel units. Mounting

requires 1/2" diameter clearance hole.

OPERATING TEMPERATURE:

-40 to +70

°

C (-40 to +158

°

F).

CABLE:

sensors are supplied with 6-1/2 feet of PVC-covered 2- or 3-

conductor cable. Models with QD connectors are available (page 8).

Dimension Drawing

Specifications, SP12 Sensors

SP12 Series sensors (foreground) shown with MAXI-AMP™
CD Series amplifier and logic
modules (see pages 3-6).

Models are also available with QD connectors (page 8).

7

MAXI-AMP

System

Advertising