Timing logic programming, Hookup of multiple self-contained sensors, Cl5 models) – Banner MAXI-AMP Series User Manual

Page 21

Advertising
background image

LIGHT OPERATE

DARK OPERATE

DARK OPERATE

If any receiver "sees"
light

When all receivers
"see" dark

OUTPUT OCCURS
(AFTER DELAY, IF
ANY)

If any receiver "sees"
dark

When all receivers
"see" light

NO

NO

YES

(NOTE: see page 6 for
description of logic functions)

YES

LIGHT OPERATE

INVERTING JUMPER
Installed Between Module
Terminals #10 and #11

SENSOR PROGRAM:
Light or Dark Operate

LOGIC DESCRIPTION

The diagram shows switch locations,
and the table summarizes the program
switch positions.

Hookup of Multiple Self-contained Sensors

Any number of self-contained dc sensors may be wired to-
gether in parallel to a single CL Series MAXI-AMP module to
create almost any multiple-sensor logic configuration. Power
for the sensors may be obtained from MAXI-AMP 400mA
power supply CP12 (shown below) or from 1-amp model
PS120-15. The table at the right describes how the four most
frequently used multiple-sensor logic configurations may be
created.

MINI-BEAM SM312 Series and VALU-BEAM SM912 Se-
ries sensors have a switch on the back of their housings which
is used to program the sensors for LIGHT or DARK operate.
MAXI-BEAM sensors are set for LIGHT or DARK operate
using the programming ring. MULTI-BEAM sensors are
programmed for LIGHT or DARK operate with the logic
module jumper wire. OMNI-BEAMs are programmed by a
switch in the sensor block.

For ON/OFF sensor operation, light operate is equated to
normally open output, and dark operate is defined as
normally closed. EZ-BEAM sensors have both a normally
open and a normally closed output. Selection of either output
determines the LIGHT/DARK operate mode. ECONO-BEAM
sensors are not programmable and must be ordered for LIGHT
OPERATE (standard models) or DARK OPERATE (model
suffix "NC").

The addition of a jumper wire between MAXI-AMP terminals
#10 and #11 changes the input response from a low-going to
a high-going signal. This feature, combined with the selection
of LIGHT or DARK operate at the sensor, allows "AND" logic
with parallel sensor connections.

Timing Logic Programming

(CL5 models)

Settings illustrated below are factory settings. Factory settings are "underlined" in the table.

A group of ten switches located on one side of the module is used to select the timing logic for
CL5 models.

Switches #1 through #7 are used to select the logic function. Switch #8 programs the output
for either NORMALLY OPEN or NORMALLY CLOSED operation. Switches #9 and #10
program the time range(s). There are three ranges: 10 to 150 milliseconds, 0.1 to 1.5 seconds,
and 1 to 15 seconds. The programmed range will be the same for both functions of a dual timing
mode (ON & OFF DELAY, DELAYED ONE-SHOT, and REPEAT CYCLE). However,
DELAY and HOLD times are independently adjustable within the selected range.

21

LIGHT "OR"

DARK "AND"

DARK "OR"

LIGHT "AND"

105-130V ac

Brown

+V dc

Brown

+V dc

Blue

(#1)

White

+V dc

Brown

105-130V AC

Blue

(#1)

SM31R/RL

White

SM31R/RL

SM31E/EL

Blue

(#1)

Brown

+V dc

Blue

SM31R/RL

White

CL3
or
CL5
model

8

7

6

5

4

CP12

power

supply

8

7

6

5

4

9

10

11

1

2

3

SM31E/EL

Blue

(#1)

Brown

+V dc

SM31E/EL

Blue

(#1)

Brown

+V dc

9

10

11

1

2

3

ON

OFF

ON

ON

ON

ON

OFF

ON

OFF

ON

PROGRAMMING

TIMING LOGIC

#1

#2

#3

#4

#5

#6

#7

#8

#9

#10

10

ON

O
F
F

1

2

3

4

5

6

7

8

9

SWITCH

SWITCH

SWITCH

SWITCH

ON

ON

ON

ON

OFF

OFF

OFF

SWITCH

SWITCH

SWITCH

SWITCH

SWITCH

SWITCH

On/Off

On Delay

Off Delay

On and Off Delay

One-shot

Delayed One-shot

Limit

Repeat Cycle

AC Latch

DC Latch

Delay and Latch

Limit and Latch

ON

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

ON

ON

OFF

ON

ON

ON

ON

ON

ON

OFF

ON

ON

ON

ON

ON

OFF

OFF

ON

ON

ON

ON

ON

OFF

OFF

OFF

ON

ON

N/C Output

N/O Output

.15 Sec. Max. Time

1.5 Sec. Max. Time

15 Sec. Max. Time

OFF

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON