NOTE #1: power is available at pins #3 (+) and #1 (-) for an external 10 to 30V dc device
(see hookup example). Current available is 50mA at 120V ac (240V ac) line level; 40mA
at 105V ac (210V ac) line level. Alternately, the module may be powered by 12 to 28V
dc at pins #3 (+) and #1 (-). Do not connect ac voltage if using external dc power.

NOTE #2: pulling pin #9 low (to Common) will inhibit the timing, or reset the latch
of CL5 models. (See "Description of Logic Functions", page 6)
NOTE #3: pin #9 of model CL3RA and CL3RB may be connected directly to the
primary or auxiliary input of MAXI-AMP model CL5 or to Banner Plug Logic
modules.

SUPPLY VOLTAGE:

Models CL3RA, CL5RA: 105 to 130V ac,

50/60Hz (4 VA), or 12 to 28V dc* at 60mA. Models CL3RB, CL5RB:
210 to 250V ac, 50/60Hz (4 VA), or 12 to 28V dc at 60mA. *Do not
connect ac voltage if using external dc power.

OUTPUT CONFIGURATION:

all models have SPDT electro-

mechanical relay:
CONTACT RATING: 250V ac max, 24V dc max, 5 amps max.
(resistive load), 1/10 H.P. at 240V ac. Install transient suppressor
(MOV) across contacts which switch inductive loads.
CLOSURE TIME: 10 milliseconds max.
RELEASE TIME: 10 milliseconds max.
MAXIMUM SWITCHING SPEED: 20 operations/second
MECHANICAL LIFE: 20,000,000 operations
CL3 models also have a logic level current sinking NPN transistor
switch
at pin #9. See schematic below and hookup info.

AMPLIFIER:

RESPONSE SPEED: 1 millisecond
INPUT CHARACTERISTICS: input is switched when the voltage at
pin #2 is pulled below 1V dc or when less than 1K ohms is connected
between pins #2 and #1. When an inverting jumper is connected
between pins #10 and #11, input is switched when the voltage at pin #2
rises above 4.5V dc or when the impedance between pins #2 and #1
exceeds 15K ohms.
HYSTERESIS: greater than .35 volts, less than 2 volts.

MULTIPLE SENSOR HOOKUP: any number of switched output
devices may be connected in parallel to the input (see hookup example).

TIMERS (CL5 models only):

TIME RANGES: LOW range - 10 to 150 milliseconds

MIDDLE range - 0.1 to 1.5 seconds
HIGH range - 1 to 15 seconds

REPEATABILITY: +/-2% of set time over all extremes of

supply voltage and temperature

ADJUSTMENTS:

Miniature switches for setting of timing function,

timing range, and output polarity (CL5 models). 15-turn clutched
potentiometer for time setting (CL5 models).

MAXI-AMP CL Series Specifications

INDICATOR LEDs:

Red indicator LEDs for input and output

status.

CONSTRUCTION:

Rugged NORYL

®