Two-point static teach (threshold) – Banner D10 Expert with Numeric Display—Discrete User Manual

Page 5

Advertising
background image

Two-Point Static TEACH (Threshold)

Sensor positions

threshold midway

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

2nd Taught

Condition

1st Taught

Condition

Position

adjusted by

Manual Adjust

Figure 4. Static TEACH (Light Operate shown)

• Establishes a single switching threshold
• Threshold position is adjustable using “+” and “-” buttons (see

Manual Adjust

on page 11)

Static TEACH is the traditional setup method, used when two con-
ditions can be presented by the user. The sensor locates a single
sensing threshold (the switchpoint) midway between the two taught
conditions, with the Output ON condition on one side, and the Out-
put OFF condition on the other (see

Figure 4. Static TEACH (Light

Operate shown)

on page 5).

The first condition taught is the ON condition. The Output ON and
OFF conditions can be reversed by changing Light/Dark Operate
status in SETUP mode (see

Sensor Setup

on page 12 ).

Static TEACH and Manual Adjust
Discrete output:
Using Manual Adjust with Static TEACH moves
the switching threshold.
Analog output: Using Manual Adjust with Static TEACH moves
the entire span up (+) or down (-).

Contrast Values

500+

Excellent: Very stable operation.

100-500

Good: Minor sensing variables will not affect sens-

ing reliability.

32-99

Low: Minor sensing variables may affect sensing

reliability.

0-31

Marginal: Consider an alternate sensing scheme.

Figure 5. Contrast Values

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

Access Stat-
ic TEACH
Mode

Press and hold Static (-)
button > 2 seconds.

No action required; sensor is
automatically ready for 1st
TEACH condition.

• Display flashes “1St
• Arrow icon turns red

TEACH Out-
put ON Con-
dition

• Present Output ON

condition

• Click Static button

• Present Output ON con-

dition

• Single-pulse the remote

line

T

Display flashes “2nd

D10 Expert™ - Analog and Discrete Outputs

P/N 65448_web
rev. F

www.bannerengineering.com - tel: 763-544-3164

5