Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

TEACH Out-
put OFF
Condition

• Present Output OFF

condition

• Click Static button

• Present Output OFF con-

dition

• Single-pulse the remote

line

T

TEACH conditions accep-
ted

• Display flashes “PASS,”

followed by a number
(denoting contrast); see

Figure 5. Contrast Val-
ues

on page 5.

• Sensor returns to RUN

mode with new settings

• Arrow icon turns green

TEACH conditions unac-
ceptable

• Display flashes “FAIL

and returns to “1St

• Arrow icon remains red
• After 60 seconds, sen-

sor returns to RUN
mode (Arrow icon turns
green) without changing
settings

Dynamic TEACH and Adaptive Thresholds

Sensor positions

threshold midway

between taught conditions

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Darkest Taught

Condition

Lightest Taught

Condition

Position

adjusted by

Manual Adjust

Figure 6. Dynamic TEACH (Light Operate shown)

Contrast Values

500+

Excellent: Very stable operation.

100-500

Good: Minor sensing variables will not affect sens-
ing reliability.

32-99

Low: Minor sensing variables may affect sensing
reliability.

0-31

Marginal: Consider an alternate sensing scheme.

Figure 7. Dynamic Contrast Values

• TEACH on-the-fly
• Sets a single threshold
• Threshold position is adjustable using the “+” and “-” buttons

(see

Manual Adjust

on page 11)

Dynamic TEACH is used to program sensitivity during actual ma-
chine run conditions. During Dynamic TEACH, the sensor takes
multiple samples of the light and dark conditions and automatically
sets the sensitivity at the optimum level. Dynamic TEACH activates
the sensor’s adaptive threshold system, which continuously tracks
minimum and maximum signal levels, and automatically maintains
centering of the switch point between the light and dark conditions.
The adaptive threshold system remains in effect during RUN mode
to automatically adjust for changes in the light or the dark condi-
tions.
When Dynamic TEACH mode is used to program sensitivity, the
output ON state (light or dark operate) will remain as it was last
programmed. To change to either light or dark operate, use the
SETUP mode (see

Sensor Setup

on page 12).

Dynamic TEACH and Manual Adjust
Sensitivity may be adjusted at any time when the sensor is in RUN
mode by clicking the “+” and “-” buttons. However, when a manual
adjustment is made, the adaptive threshold system is disabled
(cancelled).