background image

Push Button

Remote

0.04 sec. ≤ T ≤ 0.8 sec.

Result

Access Dy-
namic
TEACH
Mode

Press and hold Dynamic
(+) button.

Hold remote line low (to
ground).

• Display flashes “dYn
• Arrow icon turns red

TEACH
Sensing
Conditions

Present Output ON/OFF
conditions while continu-
ing to hold Dynamic but-
ton.

Present Output ON/OFF con-
ditions while continuing to
hold remote line low (to
ground).

Return to
RUN Mode

Release Dynamic button. Release remote line/switch.

TEACH conditions accep-
ted

• Display flashes

PASS,” followed by a
number (denoting con-
trast); see

Figure 7. Dy-

namic Contrast Values

on page 6

• Sensor returns to RUN

mode with new settings

• Arrow icon turns green

TEACH conditions unac-
ceptable

• Display flashes “FAIL
• Arrow icon remains red
• Sensor returns to RUN

mode (Arrow icon turns
green) without chang-
ing settings

D10 Expert™ - Analog and Discrete Outputs

P/N 65448_web
rev. F

www.bannerengineering.com - tel: 763-544-3164

7