Single-point window set – Banner D10 Expert with Numeric Display—Discrete User Manual

Page 8

Advertising
background image

Single-Point Window SET

Sensor positions

window thresholds

± 100 counts from the

presented condition

Darkest

(no signal)

Most Light
(saturated

signal)

Taught

Condition

200 counts

Hysteresis

100 counts

Hysteresis

100 counts

Output OFF

Output OFF

Output ON

Sensing window size adjusted by

Manual Adjust

Figure 8. Single-Point Window SET and Hysteresis

(Light Operate shown)

• Sets a single ON condition that extends 200 counts above and below

the taught condition (including ±100 counts hysteresis)

• All other conditions (lighter or darker) result in OFF output
• Sensing window size (sensitivity) is adjustable using “+” and “-” buttons

(see

Manual Adjust

on page 11)

Window SET is most useful when a product may not always appear in the
same place, or when other signals may appear. Window SET designates a
sensing window, with the Output ON condition inside the window, and the
Output OFF conditions outside the window (see

Figure 8. Single-Point

Window SET and Hysteresis (Light Operate shown)

on page 8). The sen-

sor accepts a single sensing condition, and adds switching thresholds and
hysteresis above and below that condition to create a sensing window.
Output ON and OFF conditions can be reversed by changing Light/Dark
Operate status in SETUP mode.
Window SET and Manual Adjust
Discrete:
Using Manual Adjust with Window SET expands or contracts the
size of the window.
Analog: Analog manual adjust increases (+) or decreases (-) counts on
both ends by the same amount, but it does not rescale. Cycling the power
will rescale the window and adjustments.

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

Access SET
Mode

Press and hold Static (-)
button > 2 seconds.

• Display flashes “1St
• Arrow icon turns red

• Present sensing condi-

tion

• Single-pulse the remote

line

T

• Display flashes “2nd
• Arrow icon turns red

SET Sens-
ing Condi-
tion

• Present sensing con-

dition

• Double-click Static

button

Double-pulse the remote
line.

T

T

T

TEACH conditions accep-
ted

• Display flashes “Sn6l,”

then "Pt" twice

• Sensor returns to RUN

mode with new settings

• Arrow icon turns green

TEACH conditions unac-
ceptable

• Display flashes “FAIL

and returns to “1St

• Arrow icon remains red

D10 Expert™ - Analog and Discrete Outputs

8

www.bannerengineering.com - tel: 763-544-3164

P/N 65448_web

rev. F