Single-point light set - discrete only – Banner D10 Expert with Numeric Display—Discrete User Manual

Page 9

Advertising
background image

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

• After 60 seconds, sen-

sor returns to RUN
mode (Arrow icon turns
green) without chang-
ing settings

Single-Point Light SET - Discrete Only

Threshold position

adjusted by

Manual Adjust

Sensor positions
threshold slightly below
the presented condition

Darkest

(no signal)

Most Light

(saturated

signal)

Output OFF

Output ON

Condition
Presented

Figure 9. Single-Point Light SET (Light Operate

shown)

• Sets a threshold slightly below the taught condition (see

Figure 9. Sin-

gle-Point Light SET (Light Operate shown)

on page 9)

• Any condition darker than the threshold condition causes the output to

change state

• Threshold position is adjustable using the “+” and “-” buttons (see

Man-

ual Adjust

on page 11)

• Recommended for applications where only one condition is known, for

example a stable light background with varying darker targets

A single sensing condition is presented, and the sensor positions a thresh-
old slightly below the presented condition. When a condition darker than
the threshold is sensed, the output either turns ON or OFF, depending on
the Light/Dark Operate setting (see

Sensor Setup

on page 12).

Mode

Threshold Offset (counts be-

low taught signal value)

Super High-Speed

30

High-Speed

22

High-Power

9

Super High-Power

6

Figure 10. Light SET Threshold Offset

Light SET and Light/Dark Operate Selection
Light SET teaches the Output OFF condition and forces the sensor into
Dark Operate (DO) mode. The sensor can be reconfigured to Light Operate
(LO) mode after the condition has been taught (see

Sensor Setup

on page

12).

Push Button

Remote

0.04 seconds < T < 0.8 seconds

Result

Access SET
Mode

Press and hold Static (-)
button > 2 seconds.

Single-pulse the remote line.

T

Push Button

• Display flashes “1St
• Arrow icon turns red

Remote

• Display flashes “2nd
• Arrow icon turns red

SET Output
OFF Condi-
tion

• Present Output OFF

condition

• Four-click Static but-

ton

• Present Output OFF con-

dition

• Four-pulse the remote

line

Threshold condition ac-
cepted

• Display flashes “Sn6l,”

then "Lt" twice

D10 Expert™ - Analog and Discrete Outputs

P/N 65448_web
rev. F

www.bannerengineering.com - tel: 763-544-3164

9