Single-point light set - discrete only – Banner D10 Expert with Numeric Display—Discrete User Manual
Page 9

Push Button
Remote
0.04 seconds < T < 0.8 seconds
Result
• After 60 seconds, sen-
sor returns to RUN
mode (Arrow icon turns
green) without chang-
ing settings
Single-Point Light SET - Discrete Only
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold slightly below
the presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Figure 9. Single-Point Light SET (Light Operate
shown)
• Sets a threshold slightly below the taught condition (see
gle-Point Light SET (Light Operate shown)
on page 9)
• Any condition darker than the threshold condition causes the output to
change state
• Threshold position is adjustable using the “+” and “-” buttons (see
• Recommended for applications where only one condition is known, for
example a stable light background with varying darker targets
A single sensing condition is presented, and the sensor positions a thresh-
old slightly below the presented condition. When a condition darker than
the threshold is sensed, the output either turns ON or OFF, depending on
the Light/Dark Operate setting (see
on page 12).
Mode
Threshold Offset (counts be-
low taught signal value)
Super High-Speed
30
High-Speed
22
High-Power
9
Super High-Power
6
Figure 10. Light SET Threshold Offset
Light SET and Light/Dark Operate Selection
Light SET teaches the Output OFF condition and forces the sensor into
Dark Operate (DO) mode. The sensor can be reconfigured to Light Operate
(LO) mode after the condition has been taught (see
12).
Push Button
Remote
0.04 seconds < T < 0.8 seconds
Result
Access SET
Mode
Press and hold Static (-)
button > 2 seconds.
Single-pulse the remote line.
T
Push Button
• Display flashes “1St”
• Arrow icon turns red
Remote
• Display flashes “2nd”
• Arrow icon turns red
SET Output
OFF Condi-
tion
• Present Output OFF
condition
• Four-click Static but-
ton
• Present Output OFF con-
dition
• Four-pulse the remote
line
Threshold condition ac-
cepted
• Display flashes “Sn6l,”
then "Lt" twice
D10 Expert™ - Analog and Discrete Outputs
P/N 65448_web
rev. F
www.bannerengineering.com - tel: 763-544-3164
9