08 primary power cable connections – Tweco 6000 CE Merlin User Manual

Page 22

Advertising
background image

INSTALLATION PROCEDURES

3-4

Manual 0-2601

3.08 Primary Power Cable

Connections

WARNING

Disconnect primary power at the source before con-
necting the primary power cable to the power sup-
ply.

The primary power cable must be supplied by the end
user and installed to the Power Supply assembly. Rec-
ommended cable sizes are specified in Appendix 1.

NOTE

Three-phase operation requires a 3-conductor cable
with ground.

1. Route the primary power cable through the strain

relief fitting in the rear panel of the Power Sup-
ply and tighten strain relief screws.

Input Power

Filter PC Board

and Bracket

Primary Power

Cable

Strain Relief

Fitting

Input Ground

Connection

A-00896

L1

L2

L3

Figure 3-6 Input Voltage Connections

2. Locate the four input connectors, flat washers, conical

spring washers, and hex locking nuts supplied with the
power supply.

3. Install the input connectors, supplied, onto each of the

input power line leads of the power cable.

Input

Connector

Input Power Cable

(One Line)

Slotted Screw

A-00908

PC Board

Power Stud

Flat Washer

Conical Spring

Washer

Hex Locking

Nut

Figure 3-7 Input Voltage Connector Installation Detail

4. Connect the input power connectors to the EMI Input

Power Filter PC Board input studs with the supplied
hex locking nuts, conical spring washers, and flat wash-
ers as follows:

• Input ground wire to G1.

• LI input line to X1.

• L2 input line to Y1.

• L3 input line to Z1.

5. Tighten the nuts being careful not to over-tighten. Refer

to the following WARNING.

WARNING

Do Not over tighten the nuts securing the input
power cable connectors as damage to the PC Board
can occur.

Advertising