12 external cable connections, A. optional rc 6010 remote control – Tweco 6000 CE Merlin User Manual

Page 31

Advertising
background image

Manual 0-2601

3-13

INSTALLATION PROCEDURES

d. Secure the shield lead (black) to the ground connec-

tion with the nut and star washer removed above.

e. Remove the nut and star washer from the other pilot

connection inside the power supply.

f. Secure the pilot lead (red) to the pilot connection with

the nut and star washer removed above.

5. Connect the Power Lead to the Master Power Supply as

follows:

a. Feed the Power Lead through the large strain relief at

the front panel of the Master Power Supply.

b. Remove the lock nut from the power connection termi-

nal inside the power supply.

Large

Strain Relief

Power Lead

Nut

Power Lead

Terminal Bolt

A-01496

Figure 3-21 Power Lead Connection at Master Power

Supply

c. Remove the power lead terminal bolt.

d. Place the Power Lead ring lug over the existing lug.

e. Secure the power lead to the connection with the bolt

and lock nut removed above.

6. Refer to the Arc Starter Box Manual and connect the other

end of the Torch Supply Leads components to the Arc
Starter Box.

7. Refer to the Arc Starter Box Manual and connect the liquid

cooled Maximizer 300 torch to the Arc Starter Box.

NOTE

Refer to the Installation sections in the Maximizer
300 Torch Instruction Manual (0-2573) for more
information on the Torch.

3.12 External Cable Connections

Depending on the options installed there are various cables to
be connected the Power Supply.

A. Optional RC 6010 Remote Control

For mechanized systems, the optional RC 6010 Remote Control
allows the operator to control all system functions from a re-
mote location. The control cable to interface the RC 6010 to the
Power Supply is available in various lengths (Refer to Section
6.04, Options and Accessories).

1. Connect the control cable to the receptacle marked RE-

MOTE CONTROL (J15) on the rear panel of the Power
Supply.

OUTPUT

TO

CONTROL

CONTROL
MODULE

MODULE

AIR

PLASMA

INPUT

INPUT

N

2

PLASMA

PLASMA

INPUT

INPUT

O

2

PLASMA

INPUT

INPUT

PLASMA GAS

PLASMA GAS

Ar/H

Ar/H

2

PLASMA

INPUT

INPUT

A-01505

Cable From

Remote Control

REMOTE CONTROL

Connector (J15)

Figure 3-22 Remote Control Interface Connection

2. Connect the other end of the control cable to the re-

ceptacle marked PS (J37) on the rear panel of the re-
mote control.

NOTE

Refer to the RC 6010 Remote Control Instruction
Manual 0-2478 for more information on the
RC6010 Remote Control including CNC.