Tweco 6000 CE Merlin User Manual

Page 45

Advertising
background image

Manual 0-2601

4-9

OPERATION

ful if the system is used to replace other units which
do not have auto-restart, or for use with motion con-
trol devices. In many applications, torch parts life may
be improved by disabling auto-restart to reduce ex-
cessive pilot arc time.

NOTE

Either pole set to 1 (on) disables auto-restart func-
tion.

A u to -R estart

F u n ctio n

SW 1-1

Po sitio n

SW 1-2

Po sitio n

Enabled

0 (O ff)

0 (O ff)

D isabled

0 (O ff)

1 (O n)

D isabled

1 (O n)

0 (O ff)

D isabled *

1 (O n)

1 (O n)

* = F actory Setting

B. Auto-Restart Mode (SW2)

ON

OFF

1 2

SW2

A-00992

Logic PC Board

Figure 4-9 Auto-Restart Mode Switch SW2 Location

Normal mode provides an immediate pilot restart
whenever the main arc is interrupted and the Auto-
Restart switch SW1 is set to ENABLE. Delayed mode
provides a gas pre-flow each time before the pilot arc

restarts. In some shape-cutting applications, it may
not be desirable to immediately restart the main arc
after the torch passes beyond the desired cutting line
(or between cuts).

NOTE

Either pole set to 1 (on) sets delayed auto-restart
function.

A u to -R esta rt

Mo d e

SW 2-1

Po sitio n

SW 2-2

Po sitio n

N o rmal *

0 (O ff)

0 (O ff)

D e laye d

0 (O ff)

1 (O n)

D e laye d

1 (O n)

0 (O ff)

D e laye d

1 (O n)

1 (O n)

* = F actory Sett ing

C. Gas Pre-Flow Delay (SW3)

ON

OFF

1 2

SW3

A-00993

Logic PC Board

Figure 4-10 Gas Pre-Flow Delay Switch SW3

Location

The pre-flow delay allows time for gases to flow to
the torch when the torch is activated. Pre-flow is im-
mediately followed by pilot arc initiation Pre-flow
durations are factory set but extended torch leads may
require longer pre-flow durations.

Advertising