INSTALLATION PROCEDURES

3-8

Manual 0-2601

5. Slide the Air Line Filter Assembly into the mounting bracket.

The Filter Assembly will snap into place.

A-01337

Hose Assembly
Filter to Plasma

Gas Input

1/4 NPT

Elbow

Filter

Assembly

Air Filter

Mounting Bracket

Plasma Gas

Input Fitting

Figure 3-9 Two Stage Air Line Filter Installation

6. Using the Filter to Plasma Gas Hose Assembly connect the

output port (OUT) of the Air Line Filter Assembly to the
Plasma Gas Input Fitting.

7. Place thread sealer on the threads of the Street Elbow on a

Y-Hose Assembly (see NOTES).

NOTES

Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.

The Y-Hose Assembly is customer supplied and is
shown to illustrate one method of connecting the
customer's air supply.

8. Connect the air supply hose from a Y-Hose Assembly

to the street elbow on the Air Line Filter input port
(IN). The Y-Hose Assembly should have already been
installed, if shop air was being used as the plasma
and secondary gases.

9. Apply thread sealer (see NOTE) to the other elbow of

the Y-Hose Assembly.

NOTE

Do Not use teflon tape as a thread sealer as small
particles of the tape may break off and cause the
small gas passage to be blocked in the torch.

A-01338

Shop Air

Gas Input

Air Filter

Assembly

Secondary Air

Gas Fitting

Y-Hose

Assembly

From Supply

Figure 3-10 Supply Hose Connections Without Gas

Control Option

10. Connect the elbow fitting to the SECONDARY (Air) 1/4

NPT fitting.

11. Connect the supply line from the air supply source to the Y-

hose assembly. The supply hose must be 3/8 in (10 mm)
minimum inside diameter to provide adequate air flow.

B. Using High-Pressure Gas Cylinders

NOTES

Refer to the regulator manufacturer’s specifica-
tions for installation and maintenance procedures.
Refer to Section 6.05, System Options and Acces-
sories, or a listing of available high-pressure regu-
lators.

Do not use an air line filter with high pressure gas
cylinders.

Examine the cylinder valves to be sure they are clean and
free of oil, grease or any foreign material. Momentarily
open each cylinder valve to blow out any dust which may
be present.

WARNING

Do not stand in front of the valve outlet when open-
ing.