CUSTOMER/OPERATOR SERVICE

5-4

Manual 0-2601

F. GAS indicator OFF, plasma and/or secondary gas

does not flow

1. RUN/SET/PURGE switch set to PURGE, secondary

mode switch set to GAS secondary

a. Normal operation (purges plasma line only,

secondary does not flow)

2. Secondary mode set to O2

a. No secondary flow is normal operation in O2

mode (but GAS indicator should be ON)

3. Low plasma pressure

a. Check plasma pressure

4. Secondary supply turned OFF (or tank empty)

a. Check secondary supply

5. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

H. No coolant pressure at gauge; COOLANT Indica-

tor may be OFF or ON

1. Coolant level is too low

a. Check coolant level in Coolant Reservoir and

add if necessary.

2. Clogged Coolant Filter Assembly (Rear Panel)

a. Remove screen from filter and clean or replace

as necessary.

3. Clogged In-Line Coolant Filter Assembly (Behind Side

Panels)

a. Remove screen from filter and clean or replace

as necessary.

4. Plugged or damaged coolant hoses

a. Inspect all coolant hoses and clean or replace

as necessary.

5. Plugged or damaged torch head

a. Inspect all torch head parts and replace as nec-

essary.

6. Defective Coolant Flow Component(s)

a. Isolate and replace component(s) per Service

Manual.

I. COOLANT indicator flashing ON and OFF

1. Air in coolant lines

a. Run pump for ten minutes to purge air from

the coolant lines before using the system.

2. Coolant Level is low

a. Check for proper coolant level at rear panel

gauge

J. Coolant CONDUCTIVITY Indicator OFF

1. Coolant conductivity is excessive.

a. Drain and replace coolant. Also check the con-

dition of the deionizer bag in the reservoir bas-
ket, if the bag is yellowish brown (straw color)
replace the bag.

2. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

K. Leaking torch connection

1. Loose torch connection

a. Check connection making sure connector is

fully seated.

L. DC indicator OFF (after pre-flow); No main

contactor closure

1. RUN/SET/PURGE switch not set to RUN

a. Normal operation, set switch to RUN position

2. Faulty torch switch, remote control, or remote pendant

a. Isolate and replace component(s) per Service

Manual.

3. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.

M. Weak or sputtering pilot; HF stays on during pilot

1. Plasma gas pressure too high

a. Adjust pressure

2. Low OCV (normal 290-350 vdc) caused by improper

connection of voltage selection bus bars

a. Check input voltage connections

3. Faulty power supply

a. Isolate and replace component(s) per Service

Manual.