04 operating unit without gas control option, Figure 4-6 optional plasma gas selection – Tweco 6000 CE Merlin User Manual

Page 40

Advertising
background image

OPERATION

4-4

Manual 0-2601

9. Remote Control and CNC Interface Connector

NOTE

For use with Remote Control RC6010 or Standoff
Control SC11. Refer to the Remote Control
(RC6010) Instruction Manual 0-2478 or the
Standoff Control (SC11) Instruction Manual 0-
2556 for more information.

REMOTE CONTROL connector (J15) used to inter-
face remote controls with mechanized systems. The
connector can be used to interface the Power Supply
with one of the following:

• Optional Remote Control (RC 6010) which al-

lows the operator to control all system func-
tions from a remote location.

• Optional SC-11 Standoff Control or other stan-

dard control (CNC) which allows the opera-
tor to control various functions of the mecha-
nized system from a remote location.

10. High Flow Water Shield

Output connector to allow the use of the Optional
High Flow Water Shield on the system.

11. CNC Cable Strain Relief

Used to secure a CNC cable to the Power Supply
when the CNC cable does not have a connector in-
stalled. The CNC cable is fed through the strain re-
lief and connected to an internal terminal strip (TB2).

12. Optional Gas Selection Interface Connector

Connector used to interface the Power Supply to the
Optional Gas Control (GC3000) Accessory. The Gas
Control Accessory connects to the connector marked
GAS CONTROL (J63).

13. Optional PLASMA GAS Selection

Optional panel with multiple ports (manifolds) for
connection to four plasma gases. The gas manifolds
are controlled by the Gas Control Accessory. Each
fitting is a 1/4 NPT type.

OUTPUT

OUTPUT

AIR

AIR

PLASMA

INPUT

N

2

PLASMA

INPUT

O

2

PLASMA

INPUT

PLASMA GAS

Ar/H

Ar/H

2

PLASMA

INPUT

A-01011

Plasma Gas

Manifold

Figure 4-6 Optional PLASMA Gas Selection

14. Optional Gas Secondary (N2) Input Fitting

Optional 1/4 NPT female gas fitting used to supply
the secondary gas (N2) to the system.

15. Optional Gas Secondary (OTHER) Input Fitting

Optional 1/4 NPT female gas fitting used to supply
the secondary gas (OTHER) to the system.

16. Parallel Cable Connector

Connector J54 is used to interface the Master Power
Supply to the Slave Power Supply.

4.04 Operating Unit Without Gas

Control Option

NOTE

This Subsection describes the normal operation of
the system without the Gas Control Option in-
stalled. Refer to Section 4.05 for systems with the
Gas Control Option installed.

This procedure should be followed at the beginning of
each shift:

WARNING

Disconnect primary power at the source before as-
sembling or disassembling power supply, torch
parts, torch and leads assemblies or adding cool-
ant.

Advertising