3-9

INSTALLATION PROCEDURES

Each cylinder must be equipped with an adjustable high-pres-
sure regulator capable of pressures up to 125 psi (8.6 bar) maxi-
mum and flows of up to 700 scfh (328 lpm) for cutting or goug-
ing.

CAUTION

Maximum input pressure to the internal regulator
on the Power Supply must not exceed 125 psi (8.6
bar).

Connect the gas supply to the Power Supply per the following:

1. Connect the black supply hose from the plasma gas regula-

tor directly to the input fitting on the rear panel of the Power
Supply marked PLASMA.

Plasma Gas

Supply Hose

Secondary Gas

Supply Hose

Secondary Gas

Fitting

Plasma Gas

Fitting

A-01503

Figure 3-11 Gas Connections Using Gas Cylinders

2. Connect the yellow supply hose from the secondary gas

regulator directly to the input fitting on the rear panel of the
Power Supply marked SECONDARY. Do not use the air line
filter with high pressure cylinders.

NOTE

A typical 50 lb. CO

2

cylinder can deliver a con-

tinuous flow rate of 35 scfh (16.5 lpm). To obtain
the required flow rate for the torch, it may be nec-
essary to manifold several CO

2

cylinders. Con-

tinuous flow requirements will depend on the spe-
cific application and duty cycle.

C. Using Water Secondary

NOTES

Tap water should only be used as a secondary gas
on machine torches.

The tap water source does not need to be deionized,
but in water systems with extremely high mineral
content a water softener is recommended.

Tap water can be used instead of a secondary gas and is
connected to the Power Supply as follows:

1. The tap water source must be capable of delivering a

minimum water pressure of 50 psi (3.5 bar) and flow
of 8 gph (35.2 lph).

2. Connect the tap water supply hose to the input of a

Water Pressure Regulator.

3. Connect the output of the water regulator to the fit-

ting marked SEC. WATER on the rear panel of the
Power Supply.

NOTE

The water source does not need to be deionized,
but in water systems with extremely high mineral
content a water softener is recommended.

OUTPUT

OUTPUT

TO

CONTROL
MODULE

MODULE

AIR

PLASMA

INPUT

INPUT

N2

PLASMA

INPUT

INPUT

O2

PLASMA

INPUT

INPUT

PLASMA GAS

PLASMA GAS

Ar/H

2

PLASMA

INPUT

INPUT

Water Secondary

Hose From Supply

Secondary Water

Fitting

A-01504

Figure 3-12 Secondary Water Connection

4. Set the SECONDARY selector switch on the front

panel of the Power Supply to the WATER position.

Advertising