Tweco 6000 CE Merlin User Manual

Page 32

Advertising
background image

INSTALLATION PROCEDURES

3-14

Manual 0-2601

B. Computer Control Interface (CNC)

NOTE

Used when Remote Control RC6010 or Standoff
Control SC11 are not used.

The computer control interface allows a mechanized system to
interface with a computer or other control device.

NOTE

Refer to Section 4.03-D for more information on
the CNC connections.

CNC cables can be interfaced to the Power Supply using
one of the following methods:

NOTE

Refer to Appendix 7 for CNC Interface Schematic.

• Connector (J15) at the rear of the Power Supply

• Internal terminal strip in the Power Supply

Depending on the equipment ordered and the cables sup-
plied connect the CNC cable per one of the following:

1. Using supplied CNC cable

Connect the supplied Power Supply/CNC Cable
to the Power Supply rear connector J15 labelled
REMOTE CONTROL.

2. Using customer supplied CNC Cable

a. Remove the Left Side Panel from the Power

Supply as viewed from the front of the unit.

b. Locate the internal terminal strip (TB2) near

the heatsink.

c. Feed the CNC cable through the small strain

relief at the rear of the Power Supply.

d. Connect the CNC cable to the terminal strip

(TB) per the following chart:

T B 2

C onnec tion

D es c ription

1

O ne S ide of E nable S ignal (Com m on)

2

O ther S ide of E nable S ignal (+ 15 v dc )

3

O ne S ide of S T A R T (Low )/S T O P
(High) S ignal (+ 15 v dc )

4

O ther S ide of S T A R T (Low )/S T O P
(High) S ignal (Com m on)

5

Not Us ed

6

Not Us ed

7

O ne S ide of P ilot S ens ing R elay (P S R )
- D ry C ontac ts

8

O ther S ide of P ilot S ens ing Relay
(P S R) - D ry Contac ts

9

O ne S ide of O K -T o-M ov e S ignal
(Refer to S ec tion 4.07)

10

O ther S ide of O K -T o-M ov e S ignal
(Refer to S ec tion 4.07)

NOTES

Connections to TB2 positions 1 through 4 are ac-
tivated with a switch or contact closure.

If Remote Control is not used the Enable Signal
circuit must be closed.

Connections TB2-7 and TB2-8 are normally open
(NO) contacts.

Connections TB2-9 and TB2-10 are selectable for
normally open (NO) contacts or 24 VAC.

e. Secure the CNC cable by tightening the two

screws on the strain relief.

f. Reinstall the Left Side Panel.

Advertising