B. Using Corner Slowdown for Mechanized

Cutting

NOTE

Corner Slowdown (CSD) is available only if the
Remote Control RC6010 is used.

The corner slowdown (CSD) function provides a re-
duction in output current which corresponds with
the reduced travel speed of a mechanized torch as it
changes direction at a sharp corner. When activated
(by CNC or other control device) corner slowdown
eliminates excessive metal removal and bottom dross
in corners.

Normally open (NO) contacts (supplied by the con-
trol device) close when the torch travel speed de-
creases through a corner. When the contacts close,
power supply output drops to a preset current level.

C. Setting CSD Output

NOTE

Corner Slowdown (CSD) is set at the RC6010
Remote Control.

OUTPUT AMPS

PLASMA

PLASMA
ENABLE

ENABLE

ON

START

REMOTE POWER SUPPLY CONTROL

CSD

(%)

0

25

75

100

50

TRAVEL

TRAVEL

SPEED

SPEED

125+
IPM

0-125
IPM

RUN

PURGE

SET

Front Panel of

RC6010 Remote Control

CSD (%)

Adjustment

A-00997

Figure 4-7 Corner Slowdown (CSD) Adjustment

The corner slowdown adjustment is located on the front
panel of the RC6010 Remote Control. The control sets
corner slowdown output to any current level from the
minimum (50 amps) to the maximum (150 amps) level of
the system. The corner slowdown output level is a per-
centage of the main output level. Typically the CSD out-
put level should not be set lower than 70% of the main
current level to insure full arc penetration during corner
slowdown.

If the cutting machine controller activates CSD (three
decimals on the display) during pierce starts it may not
be desirable to set CSD below 100% as starting current
will be reduced requiring longer pierce times.

NOTE

For electrical connections, refer to Appendix 6,
CNC Interface Schematic

D. Fold Back Feature

Should the torch tip contact the workpiece the out-
put current will immediately drop to 50 amps (100
amps with Slave Power Supply connected) to mini-
mize potential tip damage.

NOTE

The torch is not designed for drag cutting.

4.07 Optional Power Supply

Settings

NOTE

The adjustments in this sub-section should be set
in the Master Power Supply ONLY.

The following functions can be used to tailor a system for
special application requirements or unique user prefer-
ences. These functions are controlled by DIP switches lo-
cated on the Logic Control PC board in the power sup-
ply. Locate the Logic Control PC Board under the front
panel access cover and set the functions as required.

A. Auto-Restart Function (SW1)

ON

OFF

1 2

SW1

A-00991

Logic PC Board

Figure 4-8 Auto-Restart Enable Switch SW1

Location

Auto-restart provides an immediate pilot arc restart
during post-flow if the torch is brought within range
of the workpiece. Auto-restart can be switched off
so that the torch must be reactivated (via torch switch
or control device) to restart the pilot arc each time
the main arc is interrupted. This setting may be use-